Analytical-Grade Purity
Every lot released against HPLC purity, identity, and residual-solvent specifications documented on the certificate of analysis.
≥98% HPLC verified
Certified reference standards supplied lab-to-lab for HPLC, GC-MS, and QC purity verification — released with full documentation to accredited testing labs, universities, and manufacturers. Research use only.
Access is reviewed manually. Institutional and ship-to verification required.
Institutional Account
ISO/IEC 17025 · Verified partner
4
128
96
ORD-4821
Reference Standard RS-4521
ORD-4820
Reference Standard RS-3312
ORD-4817
Reference Standard RS-2907
ORD-4805
Reference Standard RS-1184
FRAMEWORKS & ALIGNMENT
ISO/IEC 17025
Aligned quality system
USP / EP
Referenced methods
ICH Q2(R1)
Method validation
cGMP-aligned
Documentation practices
21 CFR Part 11
Records integrity
GDP
Cold-chain & handling
PepBridge is not a certification body. Materials are released for research use only and supplied with documentation that references the frameworks above so your team can slot them into existing SOPs, method validations, and audit trails.
BUILT FOR
Access is scoped to institutions with the documentation infrastructure to use analytical reference standards responsibly.
Contract Testing Labs
ISO 17025Academic Research
R1 & R2 InstitutionsAnalytical CROs
Method DevelopmentPharma QC
Release TestingCompounding Pharmacies
USP 795 / 797Biotech R&D
Discovery & AssayGovernment Labs
Forensic & Reference503B Outsourcing
Batch DocumentationWHY PEPBRIDGE
PepBridge is designed for QC teams, testing labs, and research groups that need reference materials with real documentation — purity, identity, and lot-level records they can defend.
Every lot released against HPLC purity, identity, and residual-solvent specifications documented on the certificate of analysis.
≥98% HPLC verified
Each unit is tied to a lot number, synthesis record, and release date so results reproduce across your analytical runs.
Lot-linked records
A technical contact who understands method development, spec sheets, and analytical questions — not a storefront chatbot.
Direct technical contact
DOCUMENTATION, NOT MARKETING
Certificates of Analysis are generated per lot, signed by the analyst on record, and archived for retrieval. Purity, identity, and water content — released the same way your auditors expect to read them.
Analytical reference standards released against purity, identity, and moisture/residual-solvent specifications. For research and analytical use only.
A complete records set: certificate of analysis, chromatograms, spec sheet, and RUO statement — delivered with the shipment.
Every vial carries a lot number linked to its synthesis record, release date, and retained analytical data — so a result you got last quarter still reproduces this quarter.
A working contact for spec questions, method development, and reference-standard selection — staffed by people who read the chromatograms.
Structured account setup for QC labs, testing labs, and academic groups — with PO terms, ship-to verification, and repeatable reorder workflows.

PEPBRIDGE LABORATORIES
Certificate of Analysis
| Test | Specification | Result |
|---|---|---|
| Purity (HPLC, 214 nm) | ≥ 98.0 % | 99.42 % |
| Identity (LC-MS, [M+H]⁺) | 1,025.19 ± 0.5 | 1,025.21 |
| Water content (Karl Fischer) | ≤ 6.0 % | 3.8 % |
| Acetate content | ≤ 15.0 % | 8.2 % |

PEPBRIDGE LABORATORIES
Certificate of Analysis
| Test | Specification | Result |
|---|---|---|
| Purity (HPLC, 214 nm) | ≥ 98.0 % | 98.71 % |
| Identity (LC-MS, [M+H]⁺) | 1,290.48 ± 0.5 | 1,290.44 |
| Water content (Karl Fischer) | ≤ 6.0 % | 4.6 % |
| Residual TFA | ≤ 12.0 % | 6.9 % |

PEPBRIDGE LABORATORIES
Certificate of Analysis
| Test | Specification | Result |
|---|---|---|
| Purity (HPLC, 220 nm) | ≥ 97.5 % | 98.06 % |
| Identity (LC-MS, avg. mass) | 3,357.9 ± 1.0 | 3,358.1 |
| Water content (Karl Fischer) | ≤ 7.0 % | 5.1 % |
| Endotoxin (LAL, informational) | Report | < 5 EU/mg |

PEPBRIDGE LABORATORIES
Certificate of Analysis
| Test | Specification | Result |
|---|---|---|
| Purity (HPLC, 214 nm) | ≥ 98.0 % | 99.11 % |
| Identity (LC-MS, [M+H]⁺) | 898.06 ± 0.5 | 898.09 |
| Water content (Karl Fischer) | ≤ 6.0 % | 3.2 % |
| Appearance | White lyophilised solid | Conforms |
WHY THIS EXISTS
PepBridge was built for analytical teams that treat reference materials as instruments — where the COA, the lot number, and the retained data matter as much as the vial itself.
Every material is scoped, documented, and released for research and analytical use — not consumer resale.
Lot numbers, retention samples, and historical COAs are treated as first-class infrastructure.
Access is reviewed so materials stay with labs and researchers, not the open market.
PRIVATE LABEL PROGRAM
We apply your laboratory's identity to every vial label, certificate of analysis, and release record. The analytical work, the signatures, and the retention file remain unchanged — the imprint on the outside is yours.
MERIDIAN BIOANALYTICS
Analytical Reference · Series III
HELIX DIAGNOSTICS
Certified Reference Material
VECTOR ANALYTICAL
QC Reference · Grade A
PROCESS
A verified path from institutional access request to a lot released against spec — with documentation delivered before you order.
Submit your institution, use case, and materials of interest so our team can verify fit.
We verify the lab, intended analytical use, and ship-to before releasing spec sheets or pricing.
Approved accounts receive product spec sheets, representative COAs, and a formal quote for review.
On PO, materials are released with the signed COA and shipped under appropriate handling.
QUALITY SYSTEM
Analytical Release Panel
Signed COA released against purity, identity, and residual-solvent specs on every lot.
HPLC purity ≥98% with mass-spec identity confirmation retained on file.
Every unit tied to a lot number, synthesis record, and retained sample.
Research use only. Not for human or veterinary use, diagnostic, or therapeutic application.
METHODS & INSTRUMENTATION
Each lot is characterized on instrumentation your analytical team recognizes. Method summaries and chromatograms are available on request during account onboarding.
Agilent 1260 / equivalent
Positive & negative ESI
Coulometric titration
USP <467> referenced
Documented per lot
Reproducibility on request
A reference standard is only as good as the records behind it. Our job is to make sure the COA, the lot number, and the retained sample still hold up when your method is audited a year from now.
≥98%
HPLC purity
Default release specification
100%
Lots shipped with signed COA
No exceptions
1–3
Business days verification
For qualified institutions
7 yr
Records retention
COAs & lot data on file
CONTROLLED ACCESS
Access is reviewed manually so reference materials stay with qualified labs and research groups. Institutional email and verified ship-to required.
Apply
Verify
Release
Verification typically takes 1–3 business days.
VERIFICATION QUEUE
Submitted
Institution Verified
Ship-To Confirmed
Access Granted

BRAND STANDARD
PepBridge supplies analytical and QC labs with reference materials released against documented specifications, tied to retained samples, and shipped with the records your methods depend on. Strictly for research use, with qualified labs only.
Purity
≥98% by HPLC-UV
Identity
LC-MS confirmed
Traceability
Lot + retained sample
Records
COA, MSDS, chain of custody
FAQ
How verification, documentation, and RUO handling work at PepBridge.
Analytical and QC labs, testing labs, academic groups, and CROs that need documented reference materials for method development, calibration, and analytical work.
A signed certificate of analysis with purity, identity, and applicable residual-solvent data. Chromatograms and spec sheets are available on request.
Default release is ≥98% HPLC purity with mass-spec confirmed identity. Tighter specs are available for specific materials — ask during account onboarding.
No. All PepBridge materials are supplied strictly for research use only (RUO). They are not for human or veterinary use, and are not intended for diagnostic or therapeutic application.
We verify the institution, ship-to, and stated analytical use before releasing spec sheets or pricing. This keeps materials with qualified labs.
Yes. Lot numbers link back to retained analytical data, and prior COAs can be re-issued on request for reproducibility work.